Chapter 5 Diagnostics MX-2100/2104 Installation and Operation Manual
5-4 Diagnostic Tests
Table 5-2. Activating / Deactivating the Monitoring of a Selected Channel
Step Action Key Display
1 Bring the cursor under the
top row (if not already
there).
CURSOR
2 Scroll to display TEST
OPTIONS LED in the top
row.
SCROLL Second row displays the state of the
monitoring function:
MONITOR OFF – no channel is being
monitored
MONITOR i:j – the front panel LED's show
the status of channel B of the module
installed in slot A
3 To change, bring the
cursor under the right-
hand field in the second
row and scroll to display
the desired module:
channel number or OFF.
CURSOR,
SCROLL
4 Press ENTER. ENTER If this is the only active test on this
MX-2100, the state of the front panel TEST
indicator changes